Successive-approximation-register (SAR) analog-to-digital converter (ADC) design
Targeting the test and measurement application, this section includes many topics relevant to designing with SAR ADC devices.
Current sensor and metrology architecture options
This section compares two types of current sensors used in electricity meters: current transformers and shunts.
Introduction to the TIDA-010037 reference design
This series provides an overview of the TIDA-010037 reference design which uses the ADS131M04 delta-sigma standalone ADC for sensing the voltage and current.
TIDA-010037 hardware design
This section provides an overview of the hardware used in the TIDA-010037 design.
Designing software for split-phase electricity meters that use standalone ADCs
This section covers the initialization code and algorithms that can be used to calculate metrology parameters in a split-phase system.
Calibration and metrology accuracy results
This section discusses the procedure used to calibrate the TIDA-010037 design and the results obtained with this design.
Summary
A summary of the entire “How to design high-accuracy CT-based split-phase electricity meters using standalone metrology ADCs” training series.
Current sensor and metrology architecture options
This section compares two types of current sensors used in electricity meters: current transformers and shunts.
Introduction to the TIDA-010036 reference design
This series provides an overview of the TIDA-010036 reference design which uses the ADS131M04 delta-sigma standalone ADC for sensing the voltage and current.
TIDA-010036 hardware design
An overview of the hardware used in the TIDA-010036 design, including the circuits used to translate the Mains voltage and current.
Designing software for 1-phase electricity meters that use standalone ADCs
This section covers the initialization code and algorithms that can be used to calculate metrology parameters in a single-phase system.
ADS131M04 current detection mode for detecting neutral removal tampering
This section discusses current detection mode, which is a special low-power mode of the ADS131M04 standalone ADC.
Calibration and metrology accuracy results
This section discusses the procedure used to calibrate the TIDA-010037 design and the results obtained with this design.
Summary
A summary of the entire “How to design 1-phase shunt electricity meters using standalone metrology ADCs” training series.
Electrical overstress on data converters
This series covers methods for protecting a system with an ADC with external components and how to minimize the impact of protection components on performance.
Power amplifier biasing with precision DACs and ADCs
日付:
所要時間::
2019年 8月 13日
所要時間::
04:16
This video takes a look at how a device with integrated ADCs, DACs, and temperature sensors can be used in power amplifier biasing.
Multiparameter Reference Design For Vital Sign Patient Monitor
日付:
所要時間::
2019年 6月 14日
所要時間::
03:49
This is demo of multiparameter reference design for vital sign patient monitor
Flexible interface (PRU-ICSS) for data acquisition using multiple ADCs
日付:
所要時間::
2019年 6月 3日
所要時間::
07:11
This video covers flexible interface between the PRU-ICSS and multiple ADCs to achieve simultaneous and coherent sampling (TIDA-01555).
Troubleshooting Tips: Op Amps - Offset Voltage
日付:
所要時間::
2019年 5月 30日
所要時間::
04:31
In this training we demonstrate how to verify the input offset voltage of an amplifier using the TI product datasheet test conditions.
Solve smart meter needs in metrology, backup power, wireless communications & battery monitoring
日付:
所要時間::
2019年 5月 10日
所要時間::
43:20
Introduction to new reference designs for smart meters