Comparisons between isolated shunt sensing architectures
This section compares the two isolated shunt sensing architectures and discusses which architecture is best for different system requirements.
Summary
In this section, a summary of the entire “Polyphase current measurement with isolated shunt sensors” training module is covered.
Current sensor and metrology architecture options
This section compares two types of current sensors used in electricity meters: current transformers and shunts.
Introduction to the TIDA-010037 reference design
This series provides an overview of the TIDA-010037 reference design which uses the ADS131M04 delta-sigma standalone ADC for sensing the voltage and current.
TIDA-010037 hardware design
This section provides an overview of the hardware used in the TIDA-010037 design.
Designing software for split-phase electricity meters that use standalone ADCs
This section covers the initialization code and algorithms that can be used to calculate metrology parameters in a split-phase system.
Calibration and metrology accuracy results
This section discusses the procedure used to calibrate the TIDA-010037 design and the results obtained with this design.
Summary
A summary of the entire “How to design high-accuracy CT-based split-phase electricity meters using standalone metrology ADCs” training series.
Current sensor and metrology architecture options
This section compares two types of current sensors used in electricity meters: current transformers and shunts.
Introduction to the TIDA-010036 reference design
This series provides an overview of the TIDA-010036 reference design which uses the ADS131M04 delta-sigma standalone ADC for sensing the voltage and current.
TIDA-010036 hardware design
An overview of the hardware used in the TIDA-010036 design, including the circuits used to translate the Mains voltage and current.
Designing software for 1-phase electricity meters that use standalone ADCs
This section covers the initialization code and algorithms that can be used to calculate metrology parameters in a single-phase system.
ADS131M04 current detection mode for detecting neutral removal tampering
This section discusses current detection mode, which is a special low-power mode of the ADS131M04 standalone ADC.
Calibration and metrology accuracy results
This section discusses the procedure used to calibrate the TIDA-010037 design and the results obtained with this design.
Summary
A summary of the entire “How to design 1-phase shunt electricity meters using standalone metrology ADCs” training series.
Software Frequency Response Analyzer Overview
날짜:
기간::
2014년 11월 4일
기간::
01:52
Learn more about how TI can help you more quickly tune your digital power supply design using the Software Frequency Response Analyzer, part of powerSUITE Digit
Looking for an LDO?
날짜:
기간::
2014년 11월 8일
기간::
00:32
Texas Instruments (TI) has the broadest portfolio of LDO and linear regulators for both high-performance and cost-effective solutions. Power designers can find
Isolated Shunt-Based Current & Voltage Sensing Reference Design for Protection Relays
날짜:
기간::
2015년 2월 26일
기간::
03:03
This isolated shunt based current measurement unit enables high accuracy current measurement without the use of Current Transformers (CT). The isolation is achi
IEC 61850 Demonstration of Substation Bay Controller on Beaglebone Cape Reference Design
날짜:
기간::
2015년 2월 26일
기간::
02:32
A low cost, simplified implementation of an IEC 61850 Substation Bay Controller is demonstrated by running the Triangle MicroWorks IEC 61850 stack efficiently o
TIDA-00226: Small form factor Serial-to-Ethernet Converter Reference Design
날짜:
기간::
2015년 11월 17일
기간::
03:35
This design demonstrates bi-directional switching and transmission between serial ports and Ethernet ports, which can enable legacy equipment that has only seri