Hint: separate multiple terms with commas

E.g., 02/27/2020

E.g., 02/27/2020

Hint: separate multiple terms with commas

E.g., 02/27/2020

E.g., 02/27/2020

Sort by:

184 Results

Designing multi-kW power supply systems

Date:
October 9, 2017

Duration:
35:50
Provides insight into the some of the challenges of designing multi-kW power supply systems

TI Precision Labs - Op Amps: Power Supply Rejection

Date:
December 15, 2015

Duration:
10:07
In this video we discuss the effects of changing the power supply voltage of op amps at both AC and DC.

Reference designs for high-efficiency power and motor control applications

Date:
December 8, 2016

Duration:
05:29
Learn about two TI Design reference designs created to show how GaN power stages, C2000 MCUs, and current sense amplifiers can be used together to achieve high-

How to Design a Robust, Reliable and Efficient Power Stage for Brushless DC Motor?

Learn about the design challenges for the power stage in a low voltage BLDC motor drive and understand the system solutions enabling high efficient, robust and reliable system.  Also learn about different power supply solutions for low voltage motor control.

How to Design a Robust, Reliable and Efficient Power Stage for Brushless DC Motors

Date:
April 13, 2017

Duration:
12:20
Learn about the design challenges for the power stage in a low voltage BLDC motor drive and understand solutions enabling highly efficient and reliable systems.

Dual active bridge DC:DC power stage for a level 3 (fast) EV charging station (pile)

Date:
June 27, 2019

Duration:
01:04:25
Bi-directional, dual active bridge reference design for level 3 electric vehicle charging stations.

Power Tips: Controlling Power Supplies with Multiple Loops

Date:
October 2, 2015

Duration:
02:38
Usually the output voltage of a power supply is regulated and provided to a load.  A battery charger uses two loops: one to control the output voltage and anoth
High efficiency power and motor drive systems with C2000, GaN and INA240 current sensing

Designing for high-efficiency power and motor drive applications

Learn about solutions that pair the flexibility of digital power control with C2000 MCUs and in-line current sensing with the high-power efficiency of GaN. 

Thumbnail - Power Supply Rejection Error

TI Precision Labs - Current Sense Amplifiers: Power Supply Rejection Error

Date:
December 26, 2019

Duration:
05:16
Learn more about power supply rejection error and how to minimize its effects in a current sensing application.
Troubleshooting Power supply rejection ratio amplifier amplifiers VOS input offset integrated circuit PCB printed circuit board application linear AMP offset output voltage datasheet verification failure analysis debugging debug FA customer return

Troubleshooting Tips: Op Amps - Power Supply Rejection Ratio

Date:
May 30, 2019

Duration:
04:30
In this training we demonstrate how to verify the power supply rejection ratio of an amplifier using the TI product datasheet test conditions.

TI Precision Labs - Op Amps: Power and Temperature

Date:
November 19, 2015

Duration:
17:30
In this video we discuss the power dissipation of amplifiers, the op amp thermal model, and op amp temperature ratings.

Electrical Fundamentals and Need for power systems protection

Welcome to the world of Power Systems. The first part of the session focuses on Introduction to Power Systems, Goal of Power systems protection, fundamentals of Electricity, AC or DC, Importance of electricity, Power system voltage levels and consumers of electricity. Need and Complexities in protection of power system primary Equipment like Generators, Motors, Transformers and Circuit Breakers and finally analysis of what can go wrong on a transmission line.

TI Precision Labs - Op Amps: Power and Temperature

How hot is too hot? Does my circuit need a heat sink?

This series discusses the relationship between power dissipation and temperature in op amps and shows how to calculate an amplifier's junction temperature under a variety of operating conditions using its thermal model. Absolute maximum ratings and internal thermal protection schemes are also introduced.

Low Power PIR Motion Detector Design: Analog vs. Digital Solutions

Date:
May 1, 2018

Duration:
06:22
This video covers the fundamentals of PIR motion detector design, and analyzes the differences between analog and digital solutions.

Introduction to Protection Relay and Power Systems Faults

Second part of the session explains use case for protection relay, the sequence of events during a fault, Fault Types and the approach for fault analysis. The Session also explains commonly used protection relays and application of different relays along the grid for protection of Generation, Transmission, Distribution and Industrial equipment, Evolution of protection relays from traditional mechanical, static and the current generation digital relays.

Achieving Ultra-Low Power design in Always-On and Power Cycled applications with Nanopower Op Amps and Nanotimers

Date:
December 7, 2016

Duration:
37:10
How can you implement Texas Instruments nanopower operational amplifiers and nanotimers into your Always On design? Watch this on-demand training to find out.

Getting Started with Current Sense Amplifiers, Session 15: Programming Power Settings

Date:
May 12, 2015

Duration:
08:52
Part fifteen of the Getting Started with Current Sense Amplifiers series discusses how to program program the digital output current shunt monitors for direct current and power readouts

Getting Started with Current Sense Amplifiers, Session 11: Understanding Power Supply Rejection Error

Date:
May 12, 2015

Duration:
05:15
Part eleven of the Getting Started with Current Sense Amplifiers series continues the error source discussion focusing on power supply related error.

TI Precision Labs - Op Amps: Common Mode Rejection and Power Supply Rejection

Rejection can be a good thing, especially in the case of common mode or power supply voltage errors. 

This video series discusses how changing the common mode voltage or power supply voltage on an op amp can introduce errors at both AC and DC, and how those errors are mitigated by the op amp's built-in common mode rejection and power supply rejection.

184 Results
arrow-topclosedeletedownloadmenusearchsortingArrowszoom-inzoom-out arrow-downarrow-uparrowCircle-leftarrowCircle-rightblockDiagramcalculatorcalendarchatBubble-doublechatBubble-personchatBubble-singlecheckmark-circlechevron-downchevron-leftchevron-rightchevron-upchipclipboardclose-circlecrossReferencedashdocument-genericdocument-pdfAcrobatdocument-webevaluationModuleglobehistoryClockinfo-circlelistlockmailmyTIonlineDataSheetpersonphonequestion-circlereferenceDesignshoppingCartstartoolsvideoswarningwiki