Hint: separate multiple terms with commas

E.g., 01/20/2019

E.g., 01/20/2019

Hint: separate multiple terms with commas

E.g., 01/20/2019

E.g., 01/20/2019

No locations available for this training type

Sort by:

104 Results

Wireless Network Challenges and Solutions for a Smarter Grid IoT

The Internet of Things (IoT) is now part of the smarter grid through the adoption of IPv6 communications networks. These 6LoWPAN-based networks address key concerns such as standards-based interoperability, reliability, low power, and long-distance connectivity.

Anti-tamper Techniques to Thwart Attacks on Smart Meters--Introduction: What is Meter Tampering and Why do Utility Companies Care about it

Date:
April 12, 2017

Duration:
03:42
This module covers what is meter tampering and why is this a problem for utility providers.

Anti-tamper Techniques to Thwart Attacks on Smart Meters--Introduction: Common Meter Tampering Techniques

Date:
April 12, 2017

Duration:
08:40
This module covers common meter tampering techniques.

Anti-tamper Techniques to Thwart Attacks on Smart Meters—Detecting case tamper attacks using inductive switches: Case Tamper Detection Implementations

Date:
April 12, 2017

Duration:
07:10
This module discusses the common mechanical implementation for case tamper detection and a new way to detect case openings using inductive switches

Anti-tamper Techniques to Thwart Attacks on Smart Meters— Detecting magnetic tampering using hall-effect sensors: TIDA-00839 Magnetic Tamper Detection Reference Design Features

Date:
April 12, 2017

Duration:
07:42
This module covers how to the use hall sensors, such as the DRV5033, for the low-power detection of strong magnetic fields in three dimensions.

Anti-tamper Techniques to Thwart Attacks on Smart Meters— Detecting magnetic tampering using hall-effect sensors: Magnetic Tamper Detection Testing

Date:
April 12, 2017

Duration:
06:00
This module discusses magnetic tampering tests that were performed on the TIDA-00839 reference design using the DRV5033 to detect magnetic tampering in e-meters

Anti-tamper Techniques to Thwart Attacks on Smart Meters— Hardening a meter against magnetic tamper attacks: Isolated Shunt Sensing Building Blocks

Date:
April 12, 2017

Duration:
06:00
This module explains different measurement building blocks that could be used to implement isolated shunt current sensors for poly-phase systems.

Anti-tamper Techniques to Thwart Attacks on Smart Meters— Hardening a meter against magnetic tamper attacks: Transformer Based High-Side Power Supplies

Date:
April 12, 2017

Duration:
03:12
This module covers the advantages and disadvantages of using a transformer-based power supply to power the high-side of the AMC1304

Anti-tamper Techniques to Thwart Attacks on Smart Meters— Hardening a meter against magnetic tamper attacks: Cap-Drop Based High-Side Power Supplies

Date:
April 12, 2017

Duration:
05:35
This module covers the advantages and disadvantages of using a cap drop power supply to power the high-side of the AMC1304

Anti-tamper Techniques to Thwart Attacks on Smart Meters— Summary

Date:
April 12, 2017

Duration:
01:00
In this short module, a summary of the entire “Anti-tamper Techniques to Thwart Attacks on Smart Meters” training series will be covered.

Anti-tamper Techniques to Thwart Attacks on Smart Meters

Non-technical losses (“theft”) account for billions of dollars of revenue loss for utility providers around the world as individuals are able to hack meters to slow or stop the accumulation of energy usage statistics. This loss has driven increased requirements for enhancing the protection designed into new smart meters.  This training session will discuss different methods of attacking smart meters and how TI’s analog portfolio can be used to detect or even prevent these attacks. In one scenario magnets are used to saturate any transformers present in the system.

Electrical Fundamentals and Need for power systems protection

Date:
April 14, 2017

Duration:
13:01
This session provides a quick introduction to electrical power systems fundamentals, the need for protection in power systems and challenges for protection. 

Introduction to Protection Relay and Power Systems Faults

Date:
April 15, 2017

Duration:
10:06
This session provides Introduction to protection relay, power systems faults and  application of protection relay in power generation

AC Analog Input Module Architecture (AIM)

Date:
April 15, 2017

Duration:
11:23
Covers use cases for AC analog input module in protection relays.

High Accuracy AC Analog Input Module for Voltage & Current measurement using High Resolution Precision ADC for Protection Relay

Welcome to the world of Power Systems. This Training session covers Quick Introduction to Power Systems and need for protection relay, Protection Relay Modular Architecture, AC Analog input Module (AIM), Key Specifications, Time and Frequency domain analysis, Coherent, Simultaneous and over sampling,   Selection of ADC and other key components and TI solutions. Design details for TI design TIDA-00834 and Links to TI designs customer can refer when designing AIM.

Ultrasonic water meters have improved accuracy and precision to detect the smallest leaks to reduce water waste.

Ultrasonic Sensing for More Accurate and Precise Water Flow Meters

Ultrasonic sensing techniques have been popular in smart water meters because the technology avoids any moving parts which are prone to degrade over the lifetime of the product. The MSP430FR6047 microcontroller (MCU) family takes ultrasonic sensing solutions to next level of performance delivering <25ps of accuracy, detection of low flow rates <1 liter/hour and high precision of <5ps.

Why to prefer using gauge in primary cell and rarely discharged applications over a maintenance cycle?

Date:
October 5, 2017

Duration:
39:09
This technical training reviews several unique algorithms available in TI battery gauge products focused on primary cell batteries and rarely discharged systems
10kW 3-Phase 3-Level SiC Grid Tie Inverter Reference Design

10kW 3-Phase 3-Level SiC Grid Tie Inverter Reference Design

Date:
March 7, 2018

Duration:
04:59
Highlights TI's verified reference design that provides an overview on how to implement a three-level, three phase SiC based DC:AC grid-tie inverter stage

Overview of precise temperature measurement for heat meters

Date:
April 11, 2018

Duration:
02:25
TI’s ADS1220 Delta-Sigma converter enables precise Differential Temperature Measurement in heat and cold meter applications with standard PT sensors

RTD sensors for industrial applications

Date:
April 11, 2018

Duration:
05:21
Resistance Temperature Detectors (RTDs) offer linearity, long-term stability and repeatability over an extended temperature range
104 Results
arrow-topclosedeletedownloadmenusearchsortingArrowszoom-inzoom-out arrow-downarrow-uparrowCircle-leftarrowCircle-rightblockDiagramcalculatorcalendarchatBubble-doublechatBubble-personchatBubble-singlecheckmark-circlechevron-downchevron-leftchevron-rightchevron-upchipclipboardclose-circlecrossReferencedashdocument-genericdocument-pdfAcrobatdocument-webevaluationModuleglobehistoryClockinfo-circlelistlockmailmyTIonlineDataSheetpersonphonequestion-circlereferenceDesignshoppingCartstartoolsvideoswarningwiki