Filters in use:
Filters in use:
Filters in use:
Filters in use:
Filters in use:
Sort by:
10kW 3-Phase 3-Level SiC T-Type Inverter Reference Design
Date:
Duration:
March 7, 2018
Duration:
04:59
Highlights TI's verified reference design that provides an overview on how to implement a three-level, three phase SiC based DC:AC T-type inverter stage
6LoWPAN RF mesh demo and summary
Date:
Duration:
May 4, 2018
Duration:
06:39
This session will show a 6LoWPAN mesh demo and then conclude our discussion with summary.
6LoWPAN RF Mesh Reference Design
Date:
Duration:
April 13, 2018
Duration:
03:43
Watch a demonstration of a 6-hop mesh network data collector for smart meters, featuring the 6LoWPAN RF Mesh Reference Design.
A Deep Dive into Current and Voltage Sensing Architectures for EV and Solar Inverter Systems
Date:
Duration:
May 21, 2018
Duration:
01:06:05
A Deep Dive into Current and Voltage Sensing Architectures for EV and Solar Inverter Systems
AC analog input module (AIM) architecture
The third part of the session provides details on the need to focus on the AC AIM and its use cases in different types of protection relays.
AC and DC charging (pile) station design considerations
Gain a deep dive into common design consideration for a Level 1, 2 or 3 EV charging (pile) station and explore the service equipment block diagram for each.
ADS131M04 current detection mode for detecting neutral removal tampering
This section discusses current detection mode, which is a special low-power mode of the ADS131M04 standalone ADC.
AFE031 - Integrated Analog Front End for Power Line Comm
Date:
Duration:
November 1, 2014
Duration:
03:04
A Smart Grid Solution Functional Overview: Enabling the Smart Grid, Power Line Communications is a cost effective way to implement low data rate communica
Anti-tamper techniques to thwart attacks on smart meters
This training discusses different methods of attacking smart meters and how our analog portfolio can be used to detect or even prevent these attacks.
Anti-tamper Techniques to Thwart Attacks on Smart Meters--Introduction: Common Meter Tampering Techniques
Date:
Duration:
April 12, 2017
Duration:
08:40
This module covers common meter tampering techniques.
Anti-tamper Techniques to Thwart Attacks on Smart Meters--Introduction: What is Meter Tampering and Why do Utility Companies Care about it
Date:
Duration:
April 12, 2017
Duration:
03:42
This module covers what is meter tampering and why is this a problem for utility providers.
Anti-tamper Techniques to Thwart Attacks on Smart Meters— Detecting magnetic tampering using hall-effect sensors: Magnetic Tamper Detection Testing
Date:
Duration:
April 12, 2017
Duration:
06:00
This module discusses magnetic tampering tests that were performed on the TIDA-00839 reference design using the DRV5033 to detect magnetic tampering in e-meters
Anti-tamper Techniques to Thwart Attacks on Smart Meters— Detecting magnetic tampering using hall-effect sensors: TIDA-00839 Magnetic Tamper Detection Reference Design Features
Date:
Duration:
April 12, 2017
Duration:
07:42
This module covers how to the use hall sensors, such as the DRV5033, for the low-power detection of strong magnetic fields in three dimensions.
Anti-tamper Techniques to Thwart Attacks on Smart Meters— Hardening a meter against magnetic tamper attacks: Cap-Drop Based High-Side Power Supplies
Date:
Duration:
April 12, 2017
Duration:
05:35
This module covers the advantages and disadvantages of using a cap drop power supply to power the high-side of the AMC1304
Anti-tamper Techniques to Thwart Attacks on Smart Meters— Hardening a meter against magnetic tamper attacks: Isolated Shunt Sensing Building Blocks
Date:
Duration:
April 12, 2017
Duration:
06:00
This module explains different measurement building blocks that could be used to implement isolated shunt current sensors for poly-phase systems.
Anti-tamper Techniques to Thwart Attacks on Smart Meters— Hardening a meter against magnetic tamper attacks: Transformer Based High-Side Power Supplies
Date:
Duration:
April 12, 2017
Duration:
03:12
This module covers the advantages and disadvantages of using a transformer-based power supply to power the high-side of the AMC1304
Anti-tamper Techniques to Thwart Attacks on Smart Meters— Summary
Date:
Duration:
April 12, 2017
Duration:
01:00
In this short module, a summary of the entire “Anti-tamper Techniques to Thwart Attacks on Smart Meters” training series will be covered.
Anti-tamper Techniques to Thwart Attacks on Smart Meters—Detecting case tamper attacks using inductive switches: Case Tamper Detection Implementations
Date:
Duration:
April 12, 2017
Duration:
07:10
This module discusses the common mechanical implementation for case tamper detection and a new way to detect case openings using inductive switches
Applications and case studies of supply voltage supervisors
Date:
Duration:
March 29, 2019
Duration:
09:03
This training video will cover applications and case-studies of voltage supervisors (reset ICs)
Battery and system monitoring for smart meters
This training covers smart meter design challenges, including how to design an AFE that allows the implementation of predictive maintenance of smart meters.