Webinar - Precision Audio Op-amps and Headphone Amplifiers

Date:
September 18, 2017

Duration:
42:25
Join a series of 4 free Webinars focusing on TI audio technologies and products!

TX Signal Chain Implementation for Wide Band and High Frequency Signal Generation

Date:
November 10, 2016

Duration:
13:45
The system design for an arbitrary waveform generator (AWG) and its functional blocks, including a discussion of the AWG amplifier path and design methodology.
Troubleshooting Power supply rejection ratio amplifier amplifiers VOS input offset integrated circuit PCB printed circuit board application linear AMP offset output voltage datasheet verification failure analysis debugging debug FA customer return

Troubleshooting Tips: Op Amps - Power Supply Rejection Ratio

Date:
May 30, 2019

Duration:
04:30
In this training we demonstrate how to verify the power supply rejection ratio of an amplifier using the TI product datasheet test conditions.
Troubleshooting amplifier amplifiers VOS input offset integrated circuit PCB printed circuit board application linear AMP offset output voltage datasheet verification failure analysis debugging debug submission FA customer return

Troubleshooting Tips: Op Amps - Offset Voltage

Date:
May 30, 2019

Duration:
04:31
In this training we demonstrate how to verify the input offset voltage of an amplifier using the TI product datasheet test conditions.
Troubleshooting amplifier amplifiers common mode rejection ratio CMRR VOS input offset integrated circuit PCB printed circuit board application linear AMP offset output voltage datasheet verification failure analysis debugging debug customer return

Troubleshooting Tips: Op Amps - Common Mode Rejection Ratio

Date:
May 30, 2019

Duration:
06:18
In this training we demonstrate how to verify the common mode rejection ratio (CMRR) of an amplifier using the TI product datasheet test conditions.
Troubleshooting amplifier amplifiers integrated circuit PCB printed circuit board application linear AMP offset output voltage datasheet verification failure analysis debugging debug

Troubleshooting Tips: Op Amps

The linear amplifier troubleshooting guide highlights various techniques to assist with application problem-solving, debugging and datasheet measurements on TI specific products. The hands-on courses aid in circuit analysis, isolate the root cause of an application non-conformance and provide detailed product level information to a TI representative. Industry experts present each topic in order to help reduce debugging time and move quickly through troubleshooting to production.

Time of Flight & LIDAR (ToF) - Optical Front End Reference Design

Time of Flight & LIDAR - Optical Front End Reference Design

Date:
December 13, 2018

Duration:
04:46
Reference design overview that showcases TI high speed amplifiers, comparators, and time-to-digital converters in a optical time of flight (ToF) system.

TI Precision Labs精密實驗室系列 - 8/21運算放大器概述Part6

Date:
September 11, 2018

Duration:
42:53
TI Precision Labs精密實驗室系列 - 運算放大器概述-stability
Fully Differential Amplifiers - Noise analysis, advanced compensation technique and variable gain FDAs

TI Precision Labs – Op Amps: Fully Differential Amplifiers – Noise Analysis, Advanced Compensation Techniques and Variable Gain FDAs

Date:
July 10, 2017

Duration:
15:55
This video discusses the various noise sources of an FDA and the effects of using large resistors in the feedback network of high-speed FDAs.
Introduction to FDAs and Differential Signaling

TI Precision Labs – Op Amps: Fully Differential Amplifiers – Introduction to FDAs and Differential Signaling

Date:
July 10, 2017

Duration:
12:21
This video discusses the basics of differential signaling, its advantages over single-ended signaling and the three basic rules that govern how an FDA operates
Fully Differential Amplifiers - Input and output, common-mode and differential-swing analysis

TI Precision Labs – Op Amps: Fully Differential Amplifiers – Input and Output, Common-Mode and Differential-Swing Analysis

Date:
July 10, 2017

Duration:
14:13
This video discusses how to estimate an FDAs common-mode and differential swing at the inputs and the outputs and its dependence on the amplifier configuration
Fully Differential Amplifiers - FDA stability and simulating phase margin

TI Precision Labs – Op Amps: Fully Differential Amplifiers – FDA Stability and Simulating Phase Margin

Date:
July 10, 2017

Duration:
17:38
This video discusses FDA stability and open-loop gain. You will also learn how to calculate and simulate with TINA-TI for FDAs.

TI Precision Labs – Op Amps: Fully Differential Amplifiers – Designing a Front-End Circuit for Driving a Differential Input ADC

Date:
November 29, 2018

Duration:
18:56
This video discusses which configuration is the better solution to drive a differential-input ADC: two discrete amplifiers or one fully differential amplifier.

TI Precision Labs - Op Amps: Vos and Ib - Lab

Date:
March 23, 2015

Duration:
12:22
In this training lab we discuss calculations, simulations, and real world measurements that reinforce the concepts in the Vos and Ib video.

TI Precision Labs - Op Amps: Vos and Ib

Date:
March 23, 2015

Duration:
14:45
In this training we discuss op amp input offset voltage and input bias current specifications and their effects on op amp performance.

TI Precision Labs - Op Amps: Power Supply Rejection

Date:
December 15, 2015

Duration:
10:07
In this video we discuss the effects of changing the power supply voltage of op amps at both AC and DC.

TI Precision Labs - Op Amps: National Instruments VirtualBench Overview

Date:
March 23, 2015

Duration:
07:23
This video gives an overview of the National Instruments VirtualBench hardware and software.

TI Precision Labs - Op Amps: Low Distortion Design 4

Date:
December 4, 2015

Duration:
13:29
In this video we discuss external sources of distortion, such as resistors, capacitors, and power supply impedance.

TI Precision Labs - Op Amps: Low Distortion Design 3

Date:
December 4, 2015

Duration:
13:59
In this video we discuss distortion sources from an op amp's output stage.

TI Precision Labs - Op Amps: Low Distortion Design 2

Date:
December 4, 2015

Duration:
19:28
In this video we discuss distortion sources from the op amp's input stage.
145 Results
arrow-topclosedeletedownloadmenusearchsortingArrowszoom-inzoom-out arrow-downarrow-uparrowCircle-leftarrowCircle-rightblockDiagramcalculatorcalendarchatBubble-doublechatBubble-personchatBubble-singlecheckmark-circlechevron-downchevron-leftchevron-rightchevron-upchipclipboardclose-circlecrossReferencedashdocument-genericdocument-pdfAcrobatdocument-webevaluationModuleglobehistoryClockinfo-circlelistlockmailmyTIonlineDataSheetpersonphonequestion-circlereferenceDesignshoppingCartstartoolsvideoswarningwiki