Hint: separate multiple terms with commas

E.g., 12/11/2019

E.g., 12/11/2019

Hint: separate multiple terms with commas

E.g., 12/11/2019

E.g., 12/11/2019

Sort by:

20 Results

What is Reinforced Isolation?

Date:
May 24, 2018

Duration:
05:00
This section of the TI Precision Labs - Isolation series will review the basics of high-voltage isolation specifications and test conditions.

Webinar series Analog Signal Chain - Session 1: Understanding Isolation Technology for Industrial Applications

Date:
May 14, 2018

Duration:
58:12
Want to know more about Isolation Technology? You're in the right place

Summary

In this section, a summary of the entire “Anti-tamper Techniques to Thwart Attacks on Smart Meters” training module would be covered.  This summary would cover the “Detecting case tamper attacks using inductive switches “, “Detecting magnetic tampering using hall-effect sensors “,  and “Hardening a meter against magnetic tamper attacks “ sections of the training series. Links will be provided for the reference designs and design tools that were discussed during this training series.

Powering Isolated Gate Drivers in HEV-EV Traction Inverters

Date:
April 30, 2019

Duration:
18:42
Powering Isolated Gate Drivers in HEV-EV Traction Inverters

Power Management for Industrial Applications II

Date:
March 13, 2018

Duration:
28:05
Learn how TI’s solutions can help you overcome common power design challenges.
Commonly-used Interface for Industrial

Overview of commonly-used interface for industrial application Part 3

Date:
December 19, 2018

Duration:
10:16
Part 3: The speaker introduces a RS485 passive equalization reference design – TIDA00790 and other useful interface references.
Commonly-used Interface for Industrial

Overview of commonly-used interface for industrial application Part 1

Date:
December 19, 2018

Duration:
10:26
Part 1: First the speaker shows the communication hierarchy of all the interface type and how it impact on the communication design. Then the training further i

Isolated Bias Power Supply Architecture and Topology Trade-offs for HEV/EVs

Date:
July 29, 2019

Duration:
28:36
Isolated Bias Power Supply Architecture and Topology Trade-offs for HEV/EVs

Introduction

This section covers what is meter tampering, why is this a problem for utility providers, and some common ways a meter is tampered.

How High-Voltage Isolation Technology Works –Surge Testing

Date:
March 1, 2018

Duration:
07:57
Want to understand how high-voltage isolation technology works? Watch and learn about surge testing for isolation.

How High-Voltage Isolation Technology Works –Reliability Testing

Date:
March 1, 2018

Duration:
09:49
Want to understand how high-voltage isolation technology works? Watch and learn about reliability testing for isolation.

How High-Voltage Isolation Technology Works – Capacitive Structure

Date:
March 1, 2018

Duration:
06:17
Want to understand how high-voltage isolation technology works? Watch and learn about TI's capacitive isolation structure.

How High-Voltage Isolation Technology Works

Want to understand how high-voltage isolation technology works? Watch and learn about reliability testing for isolation. Filmed in TI's high-voltage lab, this series of videos will focus on capacitive isolation structure, working voltage reliability, withstand voltage capability, methods for testing reliability, and more.

Hardening a meter against magnetic tamper attacks

In this section, we will cover how to harden a meter against these magnetic tamper attacks by using shunts for current sensors. For poly-phase implementations, I will go over how to use isolated delta sigma modulators to add the necessary isolation to use shunt current sensors and create magnetically immune poly-phase energy measurement systems. The TIDA-00601 and TIDA-01094 reference designs, which show how to implement a poly-phase isolated shunt measurement system, will be discussed as well as the associated AMC1304 high-side power supplies used in these designs.

Dual active bridge DC:DC power stage for a level 3 (fast) EV charging station (pile)

Date:
June 27, 2019

Duration:
01:04:25
Bi-directional, dual active bridge reference design for level 3 electric vehicle charging stations.

Detecting magnetic tampering using hall-effect sensors

For anti-tampering, it is common to try to detect the presence of a strong magnet. In this section, we will cover the use of hall sensors for low-power detection of strong magnetic fields in three dimensions.  Details on our magnetic tamper detection reference design, TIDA-00839, will be provided as well as some of the design considerations that were kept in mind when creating this reference design.  

Detecting case tamper attacks using inductive switches

The first line of defense against tampering by bypassing current, reversing connections, and disconnecting leads is the meter case. Due to this, it is common for utilities to require some form of intrusion detection system to detect when someone opens a case.  In this section, we will cover how to detect someone trying to open the case of a meter.

Anti-tamper Techniques to Thwart Attacks on Smart Meters— Hardening a meter against magnetic tamper attacks: Transformer Based High-Side Power Supplies

Date:
April 12, 2017

Duration:
03:12
This module covers the advantages and disadvantages of using a transformer-based power supply to power the high-side of the AMC1304

Anti-tamper Techniques to Thwart Attacks on Smart Meters

Non-technical losses (“theft”) account for billions of dollars of revenue loss for utility providers around the world as individuals are able to hack meters to slow or stop the accumulation of energy usage statistics. This loss has driven increased requirements for enhancing the protection designed into new smart meters.  This training session will discuss different methods of attacking smart meters and how TI’s analog portfolio can be used to detect or even prevent these attacks. In one scenario magnets are used to saturate any transformers present in the system.

South Asia Industrial Webinar

2018 South Asia Industrial Webinar Series

The topics will cover system design issue and solution for Building Automation, Power Delivery and Test & Measurement. TI experts introduce the latest technology and innovation system reference design. Discover ways to enhance the time-to-market and create safer and efficient industrial systems.

20 Results
arrow-topclosedeletedownloadmenusearchsortingArrowszoom-inzoom-out arrow-downarrow-uparrowCircle-leftarrowCircle-rightblockDiagramcalculatorcalendarchatBubble-doublechatBubble-personchatBubble-singlecheckmark-circlechevron-downchevron-leftchevron-rightchevron-upchipclipboardclose-circlecrossReferencedashdocument-genericdocument-pdfAcrobatdocument-webevaluationModuleglobehistoryClockinfo-circlelistlockmailmyTIonlineDataSheetpersonphonequestion-circlereferenceDesignshoppingCartstartoolsvideoswarningwiki