Sort by:

187 Results

A&D webinar series: Enhanced products (-EP) overview

Date:
October 19, 2020

Duration:
36:47
Watch this webinar to learn about enhanced products for aerospace & defense applications.

Digital Power Supply Design Workshop

When: 
March 3, 2020 9:00 am in Garching, Germany
Laboratory based digital power supply design workshop providing design engineers an in-depth look at the design of modern, robust switch mode power supplies.

Detecting magnetic tampering using hall-effect sensors

For anti-tampering, it is common to try to detect the presence of a strong magnet. In this section, we will cover the use of hall sensors for low-power detection of strong magnetic fields in three dimensions.  Details on our magnetic tamper detection reference design, TIDA-00839, will be provided as well as some of the design considerations that were kept in mind when creating this reference design.  

Hardening a meter against magnetic tamper attacks

In this section, we will cover how to harden a meter against these magnetic tamper attacks by using shunts for current sensors. For poly-phase implementations, I will go over how to use isolated delta sigma modulators to add the necessary isolation to use shunt current sensors and create magnetically immune poly-phase energy measurement systems. The TIDA-00601 and TIDA-01094 reference designs, which show how to implement a poly-phase isolated shunt measurement system, will be discussed as well as the associated AMC1304 high-side power supplies used in these designs.

Overview of temperature measurement in heat meters

This section introduces the heat and cold meter training series. The series covers the basics of RTD sensors and their usage in heat and cold meters, as defined in the EN1434 set of standards.

Measuring RTD sensors with Delta-Sigma ADS1220 family

ADS1220 Delta-Sigma family uses the ratiometric approach for measuring RTD sensors with the built-in current excitation source. Offset and gain calibration are required before the resistance measurement is converted into a temperature reading by the application MCU.

Differential Temperature Measurement sub-system reference design

TIDA-01526 implements a high-precision Differential Temperature Measurement (DTM) subsystem using a 24-bit, low-power, Delta-Sigma ADC. Heat and cold meter DTM subsystems typically use two 2- or 4-wire RTDs such as PT100, PT500 or PT1000 and can achieve measurement accuracy of 20 mK over a water temperature range of 3°C to 180°C. The MSP430FR6047 application MCU converts the resistance value into a temperature reading in TIDA-01526.

Digital temperature sensor replacement of RTD sensors with TMP116

The TMP116 digital precision temperature sensor for the -55 to +125ºC range achieves higher accuracy than the Class AA PT sensor with a 1-point calibration. A small PCB including TI's TPD1E10B06 or TPD1E04U04 protection devices can be sealed into a RTD metal tube and meet the EN 61000-4-2 and -4-4 levels of ESD protection. The 64-bit internal EEPROM inside TMP116 stores user defined calibration data into the digital temperature sensor, simplifying integration with application MCUs, such as MSP430FR6047, FR6989 or CC13xx/26xx wireless MCU families.

Why design with MSP430FR2355?

The MSP430FR2355 is designed to match your project needs, by adding more analog features, extending the temperature range and extending a broad MSP430 MCU portfolio.  This 4-part series showcases the MSP430FR2355 device and how it can help you solve your design challenges.

MSP430 MCUs Smart Analog Combo - Introduction & Overview

Date:
June 28, 2019

Duration:
02:32
This video introduces the smart analog combo and gives an overview of the peripheral.

Design considerations for a 10-kW 3-phase, 3-level bi-directional AC/DC, DC/AC inverter/rectifier

Date:
June 28, 2019

Duration:
01:14:17
This video provides an overview on how to implement a three-level, three-phase, SiC-based 10KW converter with bi-directional functionality.

Dual active bridge DC:DC power stage for a level 3 (fast) EV charging station (pile)

Date:
June 27, 2019

Duration:
01:04:25
Bi-directional, dual active bridge reference design for level 3 electric vehicle charging stations.
Affordable high-performance vibration monitoring

Affordable high-performance vibration monitoring

Date:
June 17, 2019

Duration:
16:22
Learn about vibration monitoring, why we need predictive maintenance, existing products and trends, and Industry 4.0 challenges.
Field transmitter and process sensors reference designs for factory automation applications

Field transmitter and process sensors reference designs for factory automation applications

Date:
May 28, 2019

Duration:
18:54
Learn about our industrial reference designs targeted for field transmitter and process sensor applications.
Webinar: Solve smart meter design needs

Solve smart meter design needs in metrology, backup power, wireless communications & battery monitoring

Date:
May 10, 2019

Duration:
43:20
Introduction to new reference designs for smart meters

Connect: Wi-Fi + Amazon Echo thermostat demo

Date:
May 8, 2019

Duration:
08:49
Today, Michael walks Adrian through a demo of a Wi-Fi enabled thermostat reference design, available on ti.com.

Low quiescent current in action: reference designs

Date:
April 4, 2019

Duration:
04:27
Overview of reference designs that meet low standby power requirements of field transmitters and battery-powered applications

Overview of industrial applications that require low quiescent current

Date:
April 3, 2019

Duration:
03:38
Introduction to industrial applications which require low standby power, specifically high-cell-count battery packs and field transmitters.
Medical patch demo

Connect: Wearable, wireless patient monitoring demo with Bluetooth 5

Date:
April 3, 2019

Duration:
07:52
This week on Connect, Wei from the medical systems team walks through an exciting wearable, wireless patch demo using Bluetooth 5 and a new TI reference design
Battery-less Z-Stack 3.x: Zigbee Green Power for Home Automation

Zigbee Green Power: Enable Battery-less Devices

Date:
April 1, 2019

Duration:
16:02
Using Zigbee Green Power, certain home automation devices may now be powered by energy harvesting solutions, reducing the environmental impact of batteries.
187 Results
arrow-topclosedeletedownloadmenusearchsortingArrowszoom-inzoom-out arrow-downarrow-uparrowCircle-leftarrowCircle-rightblockDiagramcalculatorcalendarchatBubble-doublechatBubble-personchatBubble-singlecheckmark-circlechevron-downchevron-leftchevron-rightchevron-upchipclipboardclose-circlecrossReferencedashdocument-genericdocument-pdfAcrobatdocument-webevaluationModuleglobehistoryClockinfo-circlelistlockmailmyTIonlineDataSheetpersonphonequestion-circlereferenceDesignshoppingCartstartoolsvideoswarningwiki