Electrical Fundamentals and Need for power systems protection

Welcome to the world of Power Systems. The first part of the session focuses on Introduction to Power Systems, Goal of Power systems protection, fundamentals of Electricity, AC or DC, Importance of electricity, Power system voltage levels and consumers of electricity. Need and Complexities in protection of power system primary Equipment like Generators, Motors, Transformers and Circuit Breakers and finally analysis of what can go wrong on a transmission line.

Introduction to Protection Relay and Power Systems Faults

Second part of the session explains use case for protection relay, the sequence of events during a fault, Fault Types and the approach for fault analysis. The Session also explains commonly used protection relays and application of different relays along the grid for protection of Generation, Transmission, Distribution and Industrial equipment, Evolution of protection relays from traditional mechanical, static and the current generation digital relays.

AC Analog Input Module Architecture (AIM)

The third part of the session provides details on the need to focus on AC analog input module and its use cases in different types of protection relays, Different types of current sensors and the use cases for these sensors including key advantages and dis-advantages. Explains AC analog input module architecture including block diagram showing the critical products and EERD with different subsystems identified showing different approaches for designing an AC AIM.

Selection of Key Components (ADC, Signal Conditioning Amplifier) for AC Analog Input Module (AIM)

Fourth part of the session explains representation of Voltage or Current waveforms in Time and frequency domain and also looks at the customer use case for application of Time or frequency domain Analysis. The session also explains different sampling approaches like Simultaneous sampling, Coherent sampling, Oversampling to improve system performance, criteria for ADC selection and choice between SAR and Delta-Sigma ADCs. There is a list of TI products that can be considered during the design of the AIM and finally provides overview for Focus ADCs for this session.

Design Details for TI design TIDA-00834 High Accuracy Analog Front End Using 16-Bit SAR ADC with ±10V Measurement Range Reference Design

Fifth part of the session will focus on providing detailed information on TIDA-00834 TI design.  The initial slides cover Design Overview, Features, Key Components, test Setup, market differentiators, Block Diagram with links to relevant TI Designs, EVMs and TI product used in this design. Circuit representation and detailed description for ADC interface, Voltage and Current measurement and Power supply are provided. Graphs for Voltage and Current measurement accuracy are shown; along with collaterals and TI design links that can be referred by customers during design.

Overview of temperature measurement in heat meters

This section introduces the heat and cold meter training series. The series covers the basics of RTD sensors and their usage in heat and cold meters, as defined in the EN1434 set of standards.

Measuring RTD sensors with Delta-Sigma ADS1220 family

ADS1220 Delta-Sigma family uses the ratiometric approach for measuring RTD sensors with the built-in current excitation source. Offset and gain calibration are required before the resistance measurement is converted into a temperature reading by the application MCU.

Differential Temperature Measurement sub-system reference design

TIDA-01526 implements a high-precision Differential Temperature Measurement (DTM) subsystem using a 24-bit, low-power, Delta-Sigma ADC. Heat and cold meter DTM subsystems typically use two 2- or 4-wire RTDs such as PT100, PT500 or PT1000 and can achieve measurement accuracy of 20 mK over a water temperature range of 3°C to 180°C. The MSP430FR6047 application MCU converts the resistance value into a temperature reading in TIDA-01526.

Digital temperature sensor replacement of RTD sensors with TMP116

The TMP116 digital precision temperature sensor for the -55 to +125ºC range achieves higher accuracy than the Class AA PT sensor with a 1-point calibration. A small PCB including TI's TPD1E10B06 or TPD1E04U04 protection devices can be sealed into a RTD metal tube and meet the EN 61000-4-2 and -4-4 levels of ESD protection. The 64-bit internal EEPROM inside TMP116 stores user defined calibration data into the digital temperature sensor, simplifying integration with application MCUs, such as MSP430FR6047, FR6989 or CC13xx/26xx wireless MCU families.

Designing SMART Field Transmitters and PLCs with HART: Overview of Analog Output Modules

This presentation gives an overview of 2-wire and 3-wire analog output modules for PLCs and field transmitters. It covers where analog outputs are used in industrial automation. The 2-wire and 3-wire typologies are defined and isolation cases are considered.

Designing SMART Field Transmitters and PLCs with HART: 3-wire Transmitter Design

This presentation covers 3-wire analog output circuit design. The derivation of the 3-wire transfer function is shown and design considerations are provided.

Designing SMART Field Transmitters and PLCs with HART: 2-wire Transmitter Design

This presentation covers 3-wire analog output circuit design. The derivation of the 3-wire transfer function is shown and design considerations are provided.

Designing SMART Field Transmitters and PLCs with HART: HART Overview

This presentation provides an overview of HART communication in field transmitters and PLCs. It shows how HART is implemented in both input and output modules.

Designing SMART Field Transmitters and PLCs with HART: 2-Wire Transmitter Design and HART Testing

This presentation provides a 2-wire HART enabled transmitter design example with HART testing considerations. It covers the design steps and goes over the important tests to meet HART compliance.

Specifications

How do DAC specifications change and enhance your design? Find out here. 

Resources:

Architectures

Take a look at common precision DAC architectures, and find the perfect fit for your design. 

Resources: 

Identifying the right DAC

With so many options available, how do you chose the right DAC? Let us help! 

Troubleshooting a DAC

Running into trouble?! Don't worry, the right solution is just a click away. 

Factory automation and control

Go-to information for DACs in factory automation and control applications. 

Resources: 

Communications equipment

How do DACs function in communications equipment? Find out here. 

Resources:

266 Results
arrow-topclosedeletedownloadmenusearchsortingArrowszoom-inzoom-out arrow-downarrow-uparrowCircle-leftarrowCircle-rightblockDiagramcalculatorcalendarchatBubble-doublechatBubble-personchatBubble-singlecheckmark-circlechevron-downchevron-leftchevron-rightchevron-upchipclipboardclose-circlecrossReferencedashdocument-genericdocument-pdfAcrobatdocument-webevaluationModuleglobehistoryClockinfo-circlelistlockmailmyTIonlineDataSheetpersonphonequestion-circlereferenceDesignshoppingCartstartoolsvideoswarningwiki