Hint: separate multiple terms with commas

E.g., 07/04/2020

E.g., 07/04/2020

Hint: separate multiple terms with commas

E.g., 07/04/2020

E.g., 07/04/2020

Sort by:

238 Results

Harvesting energy for electrical on-board charging

Date:
November 8, 2018
Experience TI’s fully tested 3-level T-type bidirectional AC/DC converter reference design for EV charging.

Sub-1 GHz + BLE concurrent networks

Date:
November 12, 2018
This demo shows a full 802.15.4 FH and BLE network being maintained simultaneously on a single device.
GaN grid link

Cloud-enabled 10kW GaN grid link for tomorrow’s factories

Date:
November 12, 2018

Duration:
00:52
Developed jointly by Siemens and TI.

mmWave Intelligence at the Edge

Date:
November 13, 2018

Duration:
03:29
In this video we show several indoor and outdoor examples of TI’s 60GHz mmWave sensors and how they bring intelligence and decision making to the sensor edge.
TI Siemens GaN

TI and Siemens enabling industry 4.0 with GaN

Date:
November 15, 2018

Duration:
06:14
TI and Siemens enabling industry 4.0 with GaN

How to design high-accuracy CT-based split-phase electricity meters using standalone metrology ADCs

As processing requirements for electricity meters gradually increase, it becomes increasingly difficult to find one device that meets both the processing requirements for adding advanced metrology features to smart meters while also accurately sensing metrology parameters, such as RMS voltage, RMS current, and active power.  To deal with this design challenge, one option is to use a separate metrology microcontroller and a standalone ADC.

How to design 1-phase shunt electricity meters using standalone metrology ADCs

As processing requirements for electricity meters gradually increase, it becomes increasingly difficult to find one device that meets both the processing requirements for adding advanced metrology features to smart meters while also accurately sensing metrology parameters, such as RMS voltage, RMS current and active power.  To deal with this design challenge, one option is to use a separate metrology microcontroller and a standalone ADC.

Universal data concentrator supports Ethernet, 6LoWPAN RF mesh and more

IPv6-based communications are becoming the standard choice in industrial markets such as smart meters and grid automation. The universal data concentrator design provides a complete IPv6-based network solution integrated with Ethernet backbone communication, 6LoWPAN mesh networking and more. The 6LoWPAN mesh networking, which adopts an identical layering architecture to the WI-SUN FAN, addresses key concerns such as standards-based interoperability, reliability, security and long-distance connectivity.

Interfacing multiple analog-to-digital converters on a Sitara™ processor

In this training series, we demonstrate how to use the PRU-ICSS subsystem on a Sitara processor to interface between multiple SAR ADCs using SPI.

EV Charging (Pile) Stations Design Considerations

Introduction to EV Charging (Pile) Station Standards

Learn an overview of global standards and common subsystems within Level 1, 2 and 3 public and residential EV charging (pile) stations.

EV Charging (Pile) Stations Design Considerations

EV Charging (Pile) Station Subsystem Analysis

While an EV charging station (pile) might seem like a straight forward design, there are many challenges to consider when needing to safely control the power delivery. This training module will provide further insights with a subsystem analysis alongside solution examples that help you mitigate commonly overlooked subsystems including public user interfaces, an authentication mechanism and residential communications in EV charging (pile) stations.

EV Charging (Pile) Stations Design Considerations

AC and DC Charging (Pile) Station Design Considerations

Gain a deep dive into common design consideration for a Level 1, 2 or 3 EV charging (pile) station and explore the service equipment block diagram for each.

EV Charging (Pile) Stations Design Considerations

EV Charging Station System Solutions

Explore EV charging (pile) station system solutions from TI’s design library.

Introduction

This section covers wireless network trends, key technologies, and problem statements for smart grid IoT. 

System-Level Examples for Wireless Networks on Smart Grid IoT

This section covers system-level examples for wireless networks on smart grid IoT. We will provide software- and system-level details for two system examples: 6LoWPAN-Contiki and sub-1GHz sensor to cloud industrial IoT gateway reference design. 

Summary

This section summarizes the wireless network challenges and solutions for a smarter grid IoT training series. 

Introduction

Tune in to learn more about meter tampering, why it is a problem for utility providers and some common ways a meter is tampered.

Detecting case tamper attacks using inductive switches

The first line of defense against tampering by bypassing current, reversing connections, and disconnecting leads is the meter case. Due to this, it is common for utilities to require some form of intrusion detection system to detect when someone opens a case.  In this section, we will cover how to detect someone trying to open the case of a meter.

238 Results
arrow-topclosedeletedownloadmenusearchsortingArrowszoom-inzoom-out arrow-downarrow-uparrowCircle-leftarrowCircle-rightblockDiagramcalculatorcalendarchatBubble-doublechatBubble-personchatBubble-singlecheckmark-circlechevron-downchevron-leftchevron-rightchevron-upchipclipboardclose-circlecrossReferencedashdocument-genericdocument-pdfAcrobatdocument-webevaluationModuleglobehistoryClockinfo-circlelistlockmailmyTIonlineDataSheetpersonphonequestion-circlereferenceDesignshoppingCartstartoolsvideoswarningwiki