Sort by:

173 Results

Getting started with the AFE74xx RF-sampling transceiver

Quickly evaluate the AFE7444 and/or AFE7422 RF-sampling transceiver with this series of how to videos.

Getting started with the MSP430 5xx Experimenters Board (7-part series)

This 7 Part Series with the MSP430 5xx Experimenters Board will cover the following topics:

  • Introduction
  • Active and low power mode operation
  • Mixed signal application example
  • Hardware timers to conserve power
  • Implementing a fully optimized ADC12 routine
  • MSP430 tools, resources, and conclusions

Hardening a meter against magnetic tamper attacks

In this section, we will cover how to harden a meter against these magnetic tamper attacks by using shunts for current sensors. For poly-phase implementations, I will go over how to use isolated delta sigma modulators to add the necessary isolation to use shunt current sensors and create magnetically immune poly-phase energy measurement systems. The TIDA-00601 and TIDA-01094 reference designs, which show how to implement a poly-phase isolated shunt measurement system, will be discussed as well as the associated AMC1304 high-side power supplies used in these designs.

High Frequency Challenges

Learn about how to overcome high frequency challenges using TI's series capacitor buck converter.

How to design 1-phase shunt electricity meters using standalone metrology ADCs

As processing requirements for electricity meters gradually increase, it becomes increasingly difficult to find one device that meets both the processing requirements for adding advanced metrology features to smart meters while also accurately sensing metrology parameters, such as RMS voltage, RMS current and active power.  To deal with this design challenge, one option is to use a separate metrology microcontroller and a standalone ADC.

How to design high-accuracy CT-based split-phase electricity meters using standalone metrology ADCs

As processing requirements for electricity meters gradually increase, it becomes increasingly difficult to find one device that meets both the processing requirements for adding advanced metrology features to smart meters while also accurately sensing metrology parameters, such as RMS voltage, RMS current, and active power.  To deal with this design challenge, one option is to use a separate metrology microcontroller and a standalone ADC.

How to Improve Battery Efficiency and Audio Quality with TAS5825M Audio Amplifier

As the entrance of search engine, the explosive growth in wireless speaker or AI speaker is driving the new requirements of audio amplifier - higher efficiency and better audio quality.

Facing these new challenges, TAS5825M (closed loop classD with 38W stereo output) develops a lot of advanced features compared with traditional audio amplifier, which includes:

using the fusion GUI to configure a sequencer

How to use the Fusion Digital Power Designer with UCD90x Sequencers

The Fusion Digital Power Designer is a PMBus based guided user interface (GUI) that allows users to configure TI’s family of UCD90X digital sequencers. This training series walks designers through how to work with the GUI to configure their UCD90X devices, and then manage and monitor their system accordingly.

How-to Videos

This section contains task-specific videos that demonstrate how to perform debugging techniques on embedded Linux systems.

HSR and PRP Redundancy on RT Linux Training Series

This training series looks at High Availability Seamless Redundancy (HSR) and Parallel Redundancy Protocol (PRP), which are fundamental to many of the tightly-synchronized, high-reliability systems being built today. HSR and PRP work together or separate to keep systems working even when things break so that power stays on and things keep getting built. Both of them work in the low levels of the Ethernet stack to provide the applications that they serve these fundamental capabilities.

Introduction

This section covers wireless network trends, key technologies, and problem statements for smart grid IoT. 

Introduction

Tune in to learn more about meter tampering, why it is a problem for utility providers and some common ways a meter is tampered.

Introduction to OpenCL

These videos provide an to OpenCL support on Sitara and KeyStone embedded processors.

Introduction to PRU-ICSSG

This section provides an overview of the PRU-ICSSG for Gigabit-speed industrial subsystems.
Introduction to TDA2x evaluation module

Introduction to TDA2 Evaluation Module

This section introduces the TDA2x Vision EVM Kit (TDA2EVM5777) available from TI for Jacinto TDA2 SoC. The video series provide a quick overview of the TI EVM and its capabilities for ADAS solutions along with providing information on the setup and getting started with development
Introduction to the TDA3x evaluation module

Introduction to TDA3 Evaluation Module

This section introduces the TDA3x evaluation module (TDA3XEVM) available from TI for Jacinto TDA3 SoC. The video series provide a quick overview of the TI EVM and its capabilities for ADAS solutions along with providing information on the setup and getting started with development.
Introduction to SimpleLink SDK

Introduction to the SimpleLink SDK

Provides details of the software, hardware, tools, and resource components that make up the SimpleLink SDK software development kit, with an overview of TI-RTOS concepts and labs illustrating how to use the SDK to build and port applications between SimpleLink devices.

Introduction to TIDA-010036 reference design

This section provide an overview of the TIDA-010036 reference design, which uses the ADS131M04 delta sigma standalone ADC for sensing the voltage and current necessary to calculate metrology parameters.  The TIDA-010036 design targets Class 0.5 single-phase two-wire meters with shunt current sensors and has a compact, magnetically immune cap-drop power supply to power the design from AC mains.

Introduction to TIDA-010037 reference design

This section provides an overview of the TIDA-010037 reference design, which uses the ADS131M04 delta sigma standalone ADC for sensing the voltage and current necessary to calculate metrology parameters.  The TIDA-010037 design targets Class 0.1 split-phase current transformer meters.

Introduction, value proposition and benefits

Series introduction to Mobile Smart TV and the market
173 Results
arrow-topclosedeletedownloadmenusearchsortingArrowszoom-inzoom-out arrow-downarrow-uparrowCircle-leftarrowCircle-rightblockDiagramcalculatorcalendarchatBubble-doublechatBubble-personchatBubble-singlecheckmark-circlechevron-downchevron-leftchevron-rightchevron-upchipclipboardclose-circlecrossReferencedashdocument-genericdocument-pdfAcrobatdocument-webevaluationModuleglobehistoryClockinfo-circlelistlockmailmyTIonlineDataSheetpersonphonequestion-circlereferenceDesignshoppingCartstartoolsvideoswarningwiki