注意:各項之間請以逗號分隔

例如 , 07/27/2021

例如 , 07/27/2021

注意:各項之間請以逗號分隔

例如 , 07/27/2021

例如 , 07/27/2021

排序方式:

233 結果

Introduction: What is meter tampering and why do utility companies care about it

日期:
2017年 4月 12日

時間長度:
03:42
This module covers what is meter tampering and why is this a problem for utility providers.

Introduction: Common meter tampering techniques

日期:
2017年 4月 12日

時間長度:
08:40
This module covers common meter tampering techniques.

Detecting case tamper attacks using inductive switches: Case tamper detection implementations

日期:
2017年 4月 12日

時間長度:
07:10
This module discusses the common mechanical implementation for case tamper detection and a new way to detect case openings using inductive switches

Detecting magnetic tampering using hall-effect sensors: Tamper detection magnetic sensing design

日期:
2017年 4月 12日

時間長度:
07:42
This module covers how to the use hall sensors, such as the DRV5033, for the low-power detection of strong magnetic fields in three dimensions.

Detecting magnetic tampering using hall-effect sensors: Magnetic tamper detection testing

日期:
2017年 4月 12日

時間長度:
06:00
This module discusses magnetic tampering tests that were performed on the TIDA-00839 reference design using the DRV5033 to detect magnetic tampering in e-meters

Hardening a meter against magnetic tamper attacks: Isolated shunt sensing building blocks

日期:
2017年 4月 12日

時間長度:
06:00
This module explains different measurement building blocks that could be used to implement isolated shunt current sensors for poly-phase systems.

Hardening a meter against magnetic tamper attacks: Transformer based high-side power supplies

日期:
2017年 4月 12日

時間長度:
03:12
This module covers the advantages and disadvantages of using a transformer-based power supply to power the high-side of the AMC1304

Hardening a meter against magnetic tamper attacks: Cap-drop based high-side power supplies

日期:
2017年 4月 12日

時間長度:
05:35
This module covers the advantages and disadvantages of using a cap drop power supply to power the high-side of the AMC1304

Implementing isolated shunt sensors using metrology AFEs and external isolators—Design results

日期:
2018年 5月 7日

時間長度:
02:45
This video discusses the process used to test the Polyphase Shunt Metrology with Isolated AFE Reference Design and the results.

Impact of out-of-network interference on the system performance

日期:
2018年 5月 4日

時間長度:
11:01
This session will cover overall test set-up and experimental results to show the impact of out-of-network interference on system performance.

RF mesh networking offers system performance and interoperability

This training will cover system- and software-level deep-dives on new RF 6LoWPAN mesh solutions.

Calibration overview

日期:
2019年 3月 27日

時間長度:
04:35
This module provides an overview of a procedure that can be used to calibrate a meter that has the ADS131M04.

TIDA-01639 results

日期:
2018年 9月 14日

時間長度:
03:41
This module discusses the the process used to test the TIDA-01639 reference design as well as the results obtained with this reference design.

Wireless network challenges and solutions for a smarter grid IoT

This training will cover system- and software-level deep-dives on key communication protocols which comprise a 6LoWPAN-based RF network.

Implementing isolated shunt sensors using metrology AFEs and external isolators—Metrology equations

日期:
2018年 5月 7日

時間長度:
04:24
This module discusses the process used by the MSP430I2041 to calculate metrology parameters.
Webinar: Solve smart meter design needs

Solve smart meter needs in metrology, backup power, wireless communications & battery monitoring

日期:
2019年 5月 10日

時間長度:
43:20
Introduction to new reference designs for smart meters

Introduction—Benefits of using shunt current sensors instead of current transformers

日期:
2018年 5月 7日

時間長度:
04:02
This module provides details on the characteristics of shunts and current transformer and the benefits of shunts compared to current transformers.

Introduction—Why isolation is necessary for using shunts in poly-phase systems

日期:
2018年 5月 7日

時間長度:
04:31
This module covers why isolation is necessary for using shunts in poly-phase systems.

TIDA-01639 isolated modulator reference design using standalone digital filters overview

日期:
2018年 9月 14日

時間長度:
07:40
This module discusses the details on the different components within the TIDA-01639 isolated modulator reference design.

Introduction—What is meter tampering and why do utility companies care about tampering

日期:
2018年 5月 7日

時間長度:
06:19
This module provides an introduction to what is meter tampering and why do utility companies care about it.
233 結果
arrow-topclosedeletedownloadmenusearchsortingArrowszoom-inzoom-out arrow-downarrow-uparrowCircle-leftarrowCircle-rightblockDiagramcalculatorcalendarchatBubble-doublechatBubble-personchatBubble-singlecheckmark-circlechevron-downchevron-leftchevron-rightchevron-upchipclipboardclose-circlecrossReferencedashdocument-genericdocument-pdfAcrobatdocument-webevaluationModuleglobehistoryClockinfo-circlelistlockmailmyTIonlineDataSheetpersonphonequestion-circlereferenceDesignshoppingCartstartoolsvideoswarningwiki